20 Hz v.mp4Single wire good NO AUDIO.mp420240124 201400 1.mp4  

Home HISTORYRESTORATIONDESIGN REVIEWSERVICE NOTESSCHEMATICSPHOTOSENGINEERING CHANGESFOR SALEContact Me

 

 

0024A TESTING CAPACITOR ATTRIBUTES

 

This service note will provide a method to test the change in capacity with varying voltage and compare the Ceramic and Polypropylene capacitors.  Also, we will demonstrate the aging effect and restoration of a Ceramic capacitor.

  

As you view the following tests, carefully watch for the effect that varying the voltage has on the capacity.  

  

  

TEST SETUP

 

Test 1:

 

.001uf 630v Polypropylene capacitor.

Note the capacity does not change as the 

voltage is increased.                             

TEST VIDEO

TEST 2:

  

.01uf Ceramic capacitor removed from a Hallicrafters SR-2000.  Note it has lost 25% of it's capacity through the aging process.  Also note the dramatic loss of capacity with applied voltage.

  

TEST VIDEO OF .01uf CERAMIC CAPACITOR

TEST 3:

  

.01uf Ceramic capacitor --- same as TEST 2 but baked at 150C for 40 minutes.  Note the capacity is restored to slightly above the original value, reversing the aging process.

  

TEST VIDEO OF .01UF CERAMIC CAP ABOVE RESTORED

  

  

Created with the QTH.com SiteBuilder.